In turbine applications where rugged and dependable performance with low capital investment is critical to your operation, the wise choice is a Skinner S11 Single-Stage Steam Turbine.
Over the years customers have designated Skinner as the driver of choice for their rotating equipment. As a result, they obtained power solutions for their unique operations within an affordable budget and with prompt delivery schedules. They gained a steam turbine with maximum system output with optimum use of energy that made them proud of their eco-friendly production achievements while increasing profit margins. More importantly, we gave them reliability to help them enhance productivity and boost earnings.
To date more than 20,000 of our turbines have been built and installed throughout the world providing customers with many years of outstanding operating performance driving pumps, fans, blowers, compressors, mills and electric generators.
The Skinner S11 is usually a replacement driver for small lubrication pumps requiring 50 horsepower or less when space is limited.
Standard Features
Optional Accessories
Click Here to download full schematic.
Approximate Dimensions - Inches Millimeters |
|||||||||||||||||||||||
Overall | Casing | Shaft | |||||||||||||||||||||
Frame Size | AA | AB | AC | AD | AE | AG | B DIA |
BA | D DIA |
DA | DB | DC | EB | EC | EE | EF | EG | EJ | EK | EL | U DIA |
FA | FB |
11 | 41.06 1043 |
24.75 629 |
18.31 465 |
7.81 198 |
18.12 460 |
14.68 373 |
4.00 102 |
4.75 121 |
2.00 51 |
10.25 260 |
10.50 267 |
3.25 83 |
1.37 35 |
4.00 102 |
3.00 76 |
3.00 76 |
15.21 387 |
6.12 156 |
2.37 60 |
0.75 19 |
1.25 31.8 |
3.75 95 |
9.25 235 |
Techincal |
|||||||||||||||||||||||
Model | S-11 | ||||||||||||||||||||||
Maximum Inlet Gauge Pressure (PSI/Bar) | 900/62 | ||||||||||||||||||||||
Maximum Inlet Temperature (F/C) | 900/482 | ||||||||||||||||||||||
Maximum Exhaust Gague Pressure (PSI/Bar) | 175/12 | ||||||||||||||||||||||
Speed Range (RPM) | 1000-5000 | ||||||||||||||||||||||
Wheel Pitch Diameter (IN/MM) | 11/279 | ||||||||||||||||||||||
Approx. Critical Speed (RPM) | 12,950 | ||||||||||||||||||||||
Inlet Size (ANSI, IN) | 2 | ||||||||||||||||||||||
Inlet Location (Facing Governer) | Left Side | ||||||||||||||||||||||
Exhaust Size (ANSI, IN) | 4 | ||||||||||||||||||||||
Exhaust Location - Side | Optional | ||||||||||||||||||||||
Hand Valve Available | 1 | ||||||||||||||||||||||
Approx. Maximum Rating (HP/KW) | 187-140 | ||||||||||||||||||||||
Approx. Shipping Weight (LB/KG) | 460/209 | ||||||||||||||||||||||
Direction of Rotation | Optional |